title: "Use BAS trends to diagnose ventilation faults"
description: "When hoods alarm intermittently or rooms swing pressure, I want BAS trends of valve flows, fan speeds and sash positions, so I can find mismatched response…"
author: Mapped
license: https://creativecommons.org/licenses/by/4.0/
canonical: https://rivet.mapped.com/personas/job/laboratory/lab-ventilation-commissioning-specialist/use-bas-trends-to-diagnose-ventilation-faults
---

# Use BAS trends to diagnose ventilation faults

Job to be done · Laboratory Ventilation / Commissioning Specialist (CxA for labs)

In [Maintenance](https://rivet.mapped.com/personas/category/maintenance) · for the [Laboratory Ventilation / Commissioning Specialist (CxA for labs)](https://rivet.mapped.com/personas/role/laboratory/lab-ventilation-commissioning-specialist) in [Laboratories and life-science facilities](https://rivet.mapped.com/personas/facility/laboratory)

> When hoods alarm intermittently or rooms swing pressure, I want BAS trends of valve flows, fan speeds and sash positions, so I can find mismatched response speeds or loose valves instead of re-testing blindly.

## Apps that fit

Board · Report

## Measured by

- faults diagnosed from trends
- retests avoided

## What an app needs to see

- venturi valve flow and position
- exhaust fan VFD and status
- sash position
- room DP
- face velocity per hood beside the other hoods on the same exhaust fan, with the fan's last service date and the last balancing report

## Pain points

- Pressure swings when supply and exhaust VAV components respond at different speeds
- Loose exhaust valve connections only showed with one fan running

## Who else wants this

### Data center

- Critical Facilities Manager: [Escalate and command critical events](https://rivet.mapped.com/personas/job/data-center/critical-facilities-manager/escalate-and-command-critical-events)
- Physical Security Manager (Data Center): [Coordinate incidents and severe weather](https://rivet.mapped.com/personas/job/data-center/physical-security-manager/coordinate-incidents-and-severe-weather)

### Education campuses

- Director of Environmental Health & Safety: [Close inspection findings with facilities](https://rivet.mapped.com/personas/job/education/ehs-director/close-inspection-findings-with-facilities)

### Hospitals and healthcare facilities

- Medical Gas / Plumbing Technician: [See every med gas alarm and what it serves](https://rivet.mapped.com/personas/job/healthcare/medical-gas-plumbing-technician/see-every-med-gas-alarm-and-what-it-serves)

### Laboratories and life-science facilities

- Facilities Engineer - Critical Environments / Cleanroom HVAC and Clean Utilities: [Investigate cleanroom excursions to root cause](https://rivet.mapped.com/personas/job/laboratory/critical-environments-facilities-engineer/investigate-cleanroom-excursions-to-root-cause)
- Environmental Monitoring / Cleanroom Operations Specialist: [Respond to cleanroom parameter alarms](https://rivet.mapped.com/personas/job/laboratory/environmental-monitoring-cleanroom-specialist/respond-to-cleanroom-parameter-alarms)
- Validation / Qualification Engineer (facilities, utilities, EMPQ): [Requalify rooms and utilities on time](https://rivet.mapped.com/personas/job/laboratory/validation-qualification-engineer/requalify-rooms-and-utilities-on-time)
- Manager, Engineering - Animal Research Facilities: [Replace walk through HVAC checks with live trends](https://rivet.mapped.com/personas/job/laboratory/vivarium-facilities-engineering-manager/replace-walk-through-hvac-checks-with-live-trends)

## Sources

- [Hanson: UCF CREOL 3-story expansion commissioning](https://www.hanson-inc.com/our-work/ucf-creol-3-story-expansion-cx/)
- [Engineered Systems: The Case of the Exhausted Exhaust - a lab ventilation mystery](https://www.esmagazine.com/articles/98296-the-case-of-the-exhausted-exhaust-a-lab-ventilation-mystery)
- [Honeywell/Phoenix Controls: Importance of airflow control in labs](https://www.honeywell.com/us/en/news/press-releases/importance-of-airflow-control-in-labs)
- [NIH ORF News to Use: Building Automation Systems - Part I (2013)](https://www.orf.od.nih.gov/PoliciesAndGuidelines/Documents/News%20to%20Use%20PDF%20Files/2013%20NTU/Building%20Automation%20Systems%20%e2%80%93%20Part%20I%20January%202013%20News%20to%20Use_508.pdf)
- [Eng-Tips forum: general exhaust vs fume hood exhaust in a small lab](https://www.eng-tips.com/viewthread.cfm?qid=422480)
- [WSU Facilities: Appendix 7 - Airflow control devices](https://facilities.wsu.edu/documents/2020/09/appendix-7-airflow-control-devices.pdf/)
- [Eng-Tips HVAC/R forum: Fume Hood Face Velocity (2010)](https://www.eng-tips.com/threads/fume-hood-face-velocity.285820/)

## More jobs for the Laboratory Ventilation / Commissioning Specialist (CxA for labs)

[Track commissioning of every hood and room](https://rivet.mapped.com/personas/job/laboratory/lab-ventilation-commissioning-specialist/track-commissioning-of-every-hood-and-room) · [Schedule annual hood inspections by building](https://rivet.mapped.com/personas/job/laboratory/lab-ventilation-commissioning-specialist/schedule-annual-hood-inspections-by-building)

## Every kind of facility

[Airports](https://rivet.mapped.com/personas/facility/airport) · [Cross-cutting and portfolio roles](https://rivet.mapped.com/personas/facility/cross-cutting) · [Data center](https://rivet.mapped.com/personas/facility/data-center) · [Education campuses](https://rivet.mapped.com/personas/facility/education) · [Government, civic and public-safety buildings](https://rivet.mapped.com/personas/facility/government-civic) · [Hospitals and healthcare facilities](https://rivet.mapped.com/personas/facility/healthcare) · [Laboratories and life-science facilities](https://rivet.mapped.com/personas/facility/laboratory) · [Manufacturing plants and industrial sites](https://rivet.mapped.com/personas/facility/manufacturing) · [Multifamily residential and rental housing](https://rivet.mapped.com/personas/facility/multifamily-residential) · [Office buildings and corporate workplaces](https://rivet.mapped.com/personas/facility/office) · [Retail, hospitality and venues](https://rivet.mapped.com/personas/facility/retail-hospitality) · [Transit, terminals and parking](https://rivet.mapped.com/personas/facility/transit-parking) · [Utilities and critical process infrastructure](https://rivet.mapped.com/personas/facility/utilities-infrastructure) · [Warehouses and distribution centers](https://rivet.mapped.com/personas/facility/warehouse)

## Every job category

[Uptime](https://rivet.mapped.com/personas/category/uptime) · [Maintenance](https://rivet.mapped.com/personas/category/maintenance) · [Energy](https://rivet.mapped.com/personas/category/energy) · [Sustainability](https://rivet.mapped.com/personas/category/sustainability) · [Safety](https://rivet.mapped.com/personas/category/safety) · [Compliance](https://rivet.mapped.com/personas/category/compliance) · [Security](https://rivet.mapped.com/personas/category/security) · [Space](https://rivet.mapped.com/personas/category/space) · [Occupancy](https://rivet.mapped.com/personas/category/occupancy) · [Experience](https://rivet.mapped.com/personas/category/experience) · [Cost](https://rivet.mapped.com/personas/category/cost) · [Capital planning](https://rivet.mapped.com/personas/category/capital_planning) · [Workforce](https://rivet.mapped.com/personas/category/workforce) · [Vendor](https://rivet.mapped.com/personas/category/vendor) · [Throughput](https://rivet.mapped.com/personas/category/throughput) · [Quality](https://rivet.mapped.com/personas/category/quality) · [Customer](https://rivet.mapped.com/personas/category/customer) · [IT and OT](https://rivet.mapped.com/personas/category/it_ot) · [Cleaning](https://rivet.mapped.com/personas/category/cleaning) · [Resilience](https://rivet.mapped.com/personas/category/resilience)

---

From [PersonaDB](https://rivet.mapped.com/personas), Mapped’s directory of who works in a facility and what they’re trying to get done, free to reuse under CC BY 4.0 (https://creativecommons.org/licenses/by/4.0/) with credit to Mapped. Page: https://rivet.mapped.com/personas/job/laboratory/lab-ventilation-commissioning-specialist/use-bas-trends-to-diagnose-ventilation-faults