# Keep the unit on through the cold snap

Job to be done · Power Plant Operator / Control Room Operator

In [Resilience](https://rivet.mapped.com/personas/category/resilience) · for the [Power Plant Operator / Control Room Operator](https://rivet.mapped.com/personas/role/utilities-infrastructure/power-plant-operator) in [Utilities and critical process infrastructure](https://rivet.mapped.com/personas/facility/utilities-infrastructure)

> When the forecast drops below the unit's design temperature, I want freeze-protection panel alarms, heat-trace status and the critical instrument list on one screen, so I can respond to a frozen sensing line before it trips the unit.

## Apps that fit

Alerts · Board · Checklist

## Measured by

- freeze-related trips
- heat-trace circuits faulted
- instrument lines inspected
- ambient vs design temperature margin

## What an app needs to see

- freeze protection panel alarms
- heat-trace circuit status and continuity tests
- ambient temperature and forecast
- critical instrument and transmitter list

## Pain points

- Freezing issues caused 44.2 percent of unplanned outages, derates and failures to start in February 2021; 81 percent occurred above the units' design temperature
- NERC guidance calls for operators to review cold-weather scenarios affecting instrumentation readings and alarms and to respond to freeze protection panel alarms

## Who else wants this

### Education campuses

- Maintenance Supervisor (K-12 district): [Keep boiler and alarm coverage when head custodians are out](https://rivet.mapped.com/personas/job/education/k12-maintenance-supervisor/keep-boiler-and-alarm-coverage-when-head-custodians-are-out)
- Stationary Engineer / Central Plant Operator: [Catch an abnormal condition before it trips the plant](https://rivet.mapped.com/personas/job/education/stationary-engineer-plant-operator/catch-an-abnormal-condition-before-it-trips-the-plant)

### Government, civic and public-safety buildings

- Emergency Management Coordinator / Emergency Manager: [Open shelters and cooling centers that are actually open](https://rivet.mapped.com/personas/job/government-civic/emergency-management-coordinator/open-shelters-and-cooling-centers-that-are-actually-open)

### Hospitals and healthcare facilities

- Medical Gas / Plumbing Technician: [See every med gas alarm and what it serves](https://rivet.mapped.com/personas/job/healthcare/medical-gas-plumbing-technician/see-every-med-gas-alarm-and-what-it-serves)

### Laboratories and life-science facilities

- Chemical Hygiene Officer (CHO): [Keep every hood certified and performing](https://rivet.mapped.com/personas/job/laboratory/chemical-hygiene-officer/keep-every-hood-certified-and-performing)

### Manufacturing plants and industrial sites

- Facilities Engineer / Facilities Manager (plant buildings and utilities): [Catch utility failures before the line does](https://rivet.mapped.com/personas/job/manufacturing/plant-facilities-engineer-manager/catch-utility-failures-before-the-line-does)

### Multifamily residential and rental housing

- Maintenance Supervisor / Service Manager: [Never miss a cooling failure in summer](https://rivet.mapped.com/personas/job/multifamily-residential/maintenance-supervisor-service-manager/never-miss-a-cooling-failure-in-summer)

### Utilities and critical process infrastructure

- Plant Superintendent / Plant Manager (water, wastewater, generation or central plant): [Get the plant through winter](https://rivet.mapped.com/personas/job/utilities-infrastructure/plant-superintendent/get-the-plant-through-winter)

## Sources

- [O*NET 51-8013.00 Power Plant Operators](https://www.onetonline.org/link/summary/51-8013.00)
- [FERC/NERC: Final Report on February 2021 Freeze (Winter Storm Uri)](https://www.ferc.gov/news-events/news/final-report-february-2021-freeze-underscores-winterization-recommendations)
- [NERC Reliability Guideline: Generating Unit Winter Weather Readiness, Current Industry Practices v4 (2023)](https://www.nerc.com/comm/RSTC_Reliability_Guidelines/Reliability_Guideline_Generating_Unit_Winter_Weather_Readiness_v4.pdf)

## More jobs for the Power Plant Operator / Control Room Operator

[Run rounds that catch the fault](https://rivet.mapped.com/personas/job/utilities-infrastructure/power-plant-operator/run-rounds-that-catch-the-fault) · [Balance load and purchased power live](https://rivet.mapped.com/personas/job/utilities-infrastructure/power-plant-operator/balance-load-and-purchased-power-live) · [Survive the rotating shift](https://rivet.mapped.com/personas/job/utilities-infrastructure/power-plant-operator/survive-the-rotating-shift)

## Every kind of facility

[Airports](https://rivet.mapped.com/personas/facility/airport) · [Cross-cutting and portfolio roles](https://rivet.mapped.com/personas/facility/cross-cutting) · [Data center](https://rivet.mapped.com/personas/facility/data-center) · [Education campuses](https://rivet.mapped.com/personas/facility/education) · [Government, civic and public-safety buildings](https://rivet.mapped.com/personas/facility/government-civic) · [Hospitals and healthcare facilities](https://rivet.mapped.com/personas/facility/healthcare) · [Laboratories and life-science facilities](https://rivet.mapped.com/personas/facility/laboratory) · [Manufacturing plants and industrial sites](https://rivet.mapped.com/personas/facility/manufacturing) · [Multifamily residential and rental housing](https://rivet.mapped.com/personas/facility/multifamily-residential) · [Office buildings and corporate workplaces](https://rivet.mapped.com/personas/facility/office) · [Retail, hospitality and venues](https://rivet.mapped.com/personas/facility/retail-hospitality) · [Transit, terminals and parking](https://rivet.mapped.com/personas/facility/transit-parking) · [Utilities and critical process infrastructure](https://rivet.mapped.com/personas/facility/utilities-infrastructure) · [Warehouses and distribution centers](https://rivet.mapped.com/personas/facility/warehouse)

## Every job category

[Uptime](https://rivet.mapped.com/personas/category/uptime) · [Maintenance](https://rivet.mapped.com/personas/category/maintenance) · [Energy](https://rivet.mapped.com/personas/category/energy) · [Sustainability](https://rivet.mapped.com/personas/category/sustainability) · [Safety](https://rivet.mapped.com/personas/category/safety) · [Compliance](https://rivet.mapped.com/personas/category/compliance) · [Security](https://rivet.mapped.com/personas/category/security) · [Space](https://rivet.mapped.com/personas/category/space) · [Occupancy](https://rivet.mapped.com/personas/category/occupancy) · [Experience](https://rivet.mapped.com/personas/category/experience) · [Cost](https://rivet.mapped.com/personas/category/cost) · [Capital planning](https://rivet.mapped.com/personas/category/capital_planning) · [Workforce](https://rivet.mapped.com/personas/category/workforce) · [Vendor](https://rivet.mapped.com/personas/category/vendor) · [Throughput](https://rivet.mapped.com/personas/category/throughput) · [Quality](https://rivet.mapped.com/personas/category/quality) · [Customer](https://rivet.mapped.com/personas/category/customer) · [IT and OT](https://rivet.mapped.com/personas/category/it_ot) · [Cleaning](https://rivet.mapped.com/personas/category/cleaning) · [Resilience](https://rivet.mapped.com/personas/category/resilience)

---

From [PersonaDB](https://rivet.mapped.com/personas), Mapped’s directory of who works in a facility and what they’re trying to get done, free to reuse under CC BY 4.0 (https://creativecommons.org/licenses/by/4.0/) with credit to Mapped. Page: https://rivet.mapped.com/personas/job/utilities-infrastructure/power-plant-operator/keep-the-unit-on-through-the-cold-snap