title: "Know when the screen is lying"
description: "When SCADA data freezes but stays within tolerance, I want a stale-data heartbeat alarm and per-RTU last-update times, so I can tell a quiet Sunday from…"
author: Mapped
license: https://creativecommons.org/licenses/by/4.0/
canonical: https://rivet.mapped.com/personas/job/utilities-infrastructure/power-system-dispatcher/know-when-the-screen-is-lying
---

# Know when the screen is lying

Job to be done · Power System Dispatcher / System Operator

In [IT and OT](https://rivet.mapped.com/personas/category/it_ot) · for the [Power System Dispatcher / System Operator](https://rivet.mapped.com/personas/role/utilities-infrastructure/power-system-dispatcher) in [Utilities and critical process infrastructure](https://rivet.mapped.com/personas/facility/utilities-infrastructure)

> When SCADA data freezes but stays within tolerance, I want a stale-data heartbeat alarm and per-RTU last-update times, so I can tell a quiet Sunday from thirty minutes of blindness.

## Apps that fit

Alerts · Board

## Measured by

- stale-data events
- minutes without monitoring
- RTU communication availability

## What an app needs to see

- per-point and per-RTU last-update timestamps
- ICCP link status
- state estimator mismatch
- control center UPS and generator status
- EMS function health strip: state-estimator/RTCA solution status and age, SCADA, ICCP and RTU link status, with an alarm when SCADA data is stale or the SE/RTCA solution is obsolete
- time-source health for SCADA/EMS servers and workstations: NTP source accepted/rejected, offset and jitter, and whether each redundant GPS clock is in service

## Pain points

- A SCADA failure left a transmission owner without monitoring for more than thirty minutes; frozen ICCP data stayed within tolerance and the state estimator kept solving (NERC 2013)
- An entity lost multiple RTUs and used stale data for EMS analysis for 90 minutes after a tripped 480 V breaker drained the UPS (NERC 2019)

## Who else wants this

### Airports

- Terminal / Landside Operations Manager: [Keep terminal equipment working for passengers](https://rivet.mapped.com/personas/job/airport/terminal-landside-operations-manager/keep-terminal-equipment-working-for-passengers)
- Airport Noise Abatement Officer / Specialist: [Keep the monitoring terminals calibrated and reporting](https://rivet.mapped.com/personas/job/airport/airport-noise-abatement-officer/keep-the-monitoring-terminals-calibrated-and-reporting)
- Airport Noise Abatement Officer / Specialist: [Link every complaint to the flight that caused it](https://rivet.mapped.com/personas/job/airport/airport-noise-abatement-officer/link-every-complaint-to-the-flight-that-caused-it)
- Airport Operations Agent / Airfield Operations Specialist: [Keep NOTAMs accurate](https://rivet.mapped.com/personas/job/airport/airport-operations-agent/keep-notams-accurate)
- Operations Controller / Airport Dispatcher: [Dispatch the right crew to an equipment failure](https://rivet.mapped.com/personas/job/airport/aoc-operations-controller-dispatcher/dispatch-the-right-crew-to-an-equipment-failure)
- Baggage Handling System (BHS) Manager: [Hold the om contractor to the PM program](https://rivet.mapped.com/personas/job/airport/baggage-handling-system-manager/hold-the-om-contractor-to-the-pm-program)
- Customer Experience / Guest Services Manager: [Link ASQ scores to the operational causes](https://rivet.mapped.com/personas/job/airport/customer-experience-manager/link-asq-scores-to-the-operational-causes)

### Utilities and critical process infrastructure

- Instrumentation & Controls Technician (SCADA / I&C): [Find the dead signal before operations does](https://rivet.mapped.com/personas/job/utilities-infrastructure/instrumentation-controls-technician/find-the-dead-signal-before-operations-does)

## Sources

- [NERC Lesson Learned 20130202: SCADA Failure Resulting in Loss of Monitoring Function (2013)](https://www.nerc.com/globalassets/programs/event-analysis/lessons-learned/ll20130203_scada_failure_resulting_in_loss_of_monitoring_function.pdf)
- [NERC Lesson Learned 20190801: Loss of Monitoring or Control Capability due to Power Supply Failure (2019)](https://www.nerc.com/globalassets/programs/event-analysis/lessons-learned/20190801_loss_of_monitoring_control_due_to_power_supply_failure.pdf)
- [NERC Energy Management System Performance Special Assessment (2018-2019)](https://www.nerc.com/globalassets/our-work/assessments/ems_special_assessment_march2021.pdf)
- [NERC Lesson Learned LL20250301: Loss of SCADA/EMS Monitoring and Control - GPS Clock Failure](https://www.nerc.com/globalassets/programs/event-analysis/ll20250301_loss_of_scada_ems_monitoring_control_gps_clock_failure.pdf)

## More jobs for the Power System Dispatcher / System Operator

[See the control centers own power](https://rivet.mapped.com/personas/job/utilities-infrastructure/power-system-dispatcher/see-the-control-centers-own-power) · [Restore the outage with the crew you have](https://rivet.mapped.com/personas/job/utilities-infrastructure/power-system-dispatcher/restore-the-outage-with-the-crew-you-have)

## Every kind of facility

[Airports](https://rivet.mapped.com/personas/facility/airport) · [Cross-cutting and portfolio roles](https://rivet.mapped.com/personas/facility/cross-cutting) · [Data center](https://rivet.mapped.com/personas/facility/data-center) · [Education campuses](https://rivet.mapped.com/personas/facility/education) · [Government, civic and public-safety buildings](https://rivet.mapped.com/personas/facility/government-civic) · [Hospitals and healthcare facilities](https://rivet.mapped.com/personas/facility/healthcare) · [Laboratories and life-science facilities](https://rivet.mapped.com/personas/facility/laboratory) · [Manufacturing plants and industrial sites](https://rivet.mapped.com/personas/facility/manufacturing) · [Multifamily residential and rental housing](https://rivet.mapped.com/personas/facility/multifamily-residential) · [Office buildings and corporate workplaces](https://rivet.mapped.com/personas/facility/office) · [Retail, hospitality and venues](https://rivet.mapped.com/personas/facility/retail-hospitality) · [Transit, terminals and parking](https://rivet.mapped.com/personas/facility/transit-parking) · [Utilities and critical process infrastructure](https://rivet.mapped.com/personas/facility/utilities-infrastructure) · [Warehouses and distribution centers](https://rivet.mapped.com/personas/facility/warehouse)

## Every job category

[Uptime](https://rivet.mapped.com/personas/category/uptime) · [Maintenance](https://rivet.mapped.com/personas/category/maintenance) · [Energy](https://rivet.mapped.com/personas/category/energy) · [Sustainability](https://rivet.mapped.com/personas/category/sustainability) · [Safety](https://rivet.mapped.com/personas/category/safety) · [Compliance](https://rivet.mapped.com/personas/category/compliance) · [Security](https://rivet.mapped.com/personas/category/security) · [Space](https://rivet.mapped.com/personas/category/space) · [Occupancy](https://rivet.mapped.com/personas/category/occupancy) · [Experience](https://rivet.mapped.com/personas/category/experience) · [Cost](https://rivet.mapped.com/personas/category/cost) · [Capital planning](https://rivet.mapped.com/personas/category/capital_planning) · [Workforce](https://rivet.mapped.com/personas/category/workforce) · [Vendor](https://rivet.mapped.com/personas/category/vendor) · [Throughput](https://rivet.mapped.com/personas/category/throughput) · [Quality](https://rivet.mapped.com/personas/category/quality) · [Customer](https://rivet.mapped.com/personas/category/customer) · [IT and OT](https://rivet.mapped.com/personas/category/it_ot) · [Cleaning](https://rivet.mapped.com/personas/category/cleaning) · [Resilience](https://rivet.mapped.com/personas/category/resilience)

---

From [PersonaDB](https://rivet.mapped.com/personas), Mapped’s directory of who works in a facility and what they’re trying to get done, free to reuse under CC BY 4.0 (https://creativecommons.org/licenses/by/4.0/) with credit to Mapped. Page: https://rivet.mapped.com/personas/job/utilities-infrastructure/power-system-dispatcher/know-when-the-screen-is-lying