Warehouses and distribution centers

Refrigeration Operator / Ammonia Refrigeration Technician (cold storage)

Also posted as Ammonia Refrigeration Technician, Refrigeration Technician III, Maintenance Technician - Ammonia Refrigeration, Refrigeration Operator, Industrial Refrigeration Operator, Engine Room Operator

See it in the graph

Runs and repairs the ammonia (sometimes CO2 or Freon) refrigeration plant that holds a cold-storage warehouse between -20 F and 0 F: sets operating parameters, watches compressors, condensers, evaporators and defrost cycles, troubleshoots the control system and replaces components under lockout. Keeps the preventive and predictive maintenance records that OSHA's PSM standard and EPA's RMP rule demand, and answers after-hours call-backs. In many cold stores the refrigeration technician is also the whole maintenance department, covering doors, dock boards, racks, sprinklers and forklifts.

What they do

  • Set up and define operating parameters for all refrigeration equipment; monitor system performance and adjust operations to keep it running optimally (Americold Refrigeration Technician III)
  • Troubleshoot refrigeration, electrical, mechanical and control systems to root cause and recommend fixes; replace components using lockout/tagout (Americold Refrigeration Technician III)
  • Perform routine inspections, testing and preventive maintenance on the refrigeration system and log daily work orders in the CMMS (Lineage Tacoma posting)
  • Keep accurate preventive and predictive maintenance records, including the documented mechanical-integrity inspections of vessels, piping, relief valves, alarms and interlocks that PSM requires (Americold postings; 29 CFR 1910.119(j))
  • Repair and adjust doors, dock boards, pallet racks, sweepers, sprinkler systems, forklifts, pallet trucks and electrical equipment to OSHA standards (Americold Anaheim)
  • Test safety equipment such as exit signs, fire extinguishers and sprinklers; test and calibrate HVAC equipment (Americold Anaheim)
  • Oversee and inspect work by internal and external technicians; train less experienced technicians (Americold Refrigeration Technician III)
  • Answer after-hours call-backs and work nights, weekends and overtime as needed (Americold Anaheim)

What they measure

  • room temperature excursions
  • compressor kW per machine against vendor design
  • defrost cycles completed per design sequence and dwell time
  • ammonia detector alarms and releases
  • PM and PdM completion
  • after-hours call-backs
  • PSM mechanical-integrity inspections overdue and deficiencies open
  • RMP resubmitted on the five-year cycle

Systems they use

  • ammonia refrigeration control system (ALTA and Allen-Bradley named by Americold)
  • CMMS (Oracle named by Americold)
  • compressor panels and capacity controls
  • evaporator hot-gas defrost valve groups and sequencing
  • ammonia gas detection and machine-room ventilation
  • pressure gauges, pyrometers, voltmeters and ohmmeters
  • building management system (O*NET 51-8021)
  • freezer under-slab heat trace and door heaters on the building side

Certifications

  • RETA CARO, Certified Assistant Refrigeration Operator (entry level, no experience minimum; required within 6 months in one Lineage posting)
  • RETA CIRO, Certified Industrial Refrigeration Operator (two years' documented operating experience; paid extra by Americold)
  • RETA CRST, Certified Refrigeration Service Technician (needs CARO/CIRO or four years' experience)
  • RETA CRES, Certified Refrigeration Energy Specialist (optional, energy)
  • six RETA courses within 18 months as a condition of employment (Americold Anaheim)
  • HAZMAT training and certification (Americold)
  • high level of knowledge of the OSHA PSM program (Americold Anaheim)
  • sprinkler testing certificate where the site has sprinklers (Americold Anaheim)
  • forklift certificate
  • state refrigeration operator or stationary engineer licence where required (inferred)

Jobs to be done

  • See the engine room from the warehouse floor · UptimeWhen I am across the warehouse fixing a dock door, I want suction and discharge pressures, compressor status, room temperatures and gas-detector states on my phone, so I can catch a condenser falling behind on a hot afternoon before high discharge trips a compressor. BoardAlertsMap
  • Defrost without hammering the pipes · SafetyWhen a freezer evaporator goes into hot-gas defrost, I want the pump-out, soft-gas, hot-gas and bleed steps with their dwell times logged per coil along with any alarm resets, so I can prove each sequence ran as designed and not as a control reset left it. WorkflowAlertsReport
  • Keep the PSM and RMP records matching the plant · ComplianceWhen the three-year PSM audit or the five-year RMP update comes round, I want every vessel, relief valve, alarm and interlock inspection logged with date, person and result and every change run through management of change, so I can show the auditor a plant whose records match its pipes. ChecklistReportWorkflow
  • Run the plant on the cheapest kilowatt · EnergyWhen I know the demand charge window and the off-peak rate, I want compressor kW, suction pressure and room temperature by the hour, so I can pull the freezer down off-peak, let condensing pressure float in cold weather and show the site what the engine room really costs. BoardReportSchedule

Pain points

  • Americold's Anaheim ammonia refrigeration technician posting covers repair of the refrigeration system plus doors, dock boards, pallet racks, sweepers, sprinkler systems and forklifts, and testing HVAC, with after-hours call-backs, at $39 an hour plus extra for CARO and CIRO. (heard in Ammonia Refrigeration Technician, Americold, Anaheim CA (open when read))
  • EPA alleged inadequate alarms, rusted valves, inadequate ventilation and insufficient access to emergency controls at Londonderry Freezer Warehouse, a cold-storage facility; the company paid $78,200 and spent more than $215,000 to return to compliance (2019). (heard in EPA settlement with Londonderry, NH company (2019-07-09))
  • An operator clearing alarms during troubleshooting reset a defrost cycle, and the resulting hydraulic shock released about 32,100 lb of ammonia from a rooftop suction line. (heard in CSB news release: Safety Bulletin on the Millard Refrigerated Services ammonia release (2015-01-15, incident 2010-08-23))
  • Lineage's Tacoma ammonia refrigeration technician posting (no longer accepting applications) paid $28.56-$48.17 an hour and required CARO or equivalent certification within 6 months of hire. (heard in Ammonia Refrigeration Technician ($3k sign-on bonus), Lineage, Tacoma WA (closed when read; posted 6+ months earlier))

Sources

More roles in warehouses and distribution centers

Every kind of facility

Every job category

See it in the graphAll of PersonaDBBuild an app for this role with Rivet

From PersonaDB, Mapped’s directory of who works in a facility and what they’re trying to get done. Every sourced entry links to the page it came from. PersonaDB’s words are free to reuse under CC BY 4.0 with credit to Mapped; the pages it cites keep their own terms. Cite as: “Refrigeration Operator / Ammonia Refrigeration Technician (cold storage)”, PersonaDB, Mapped, https://rivet.mapped.com/personas/role/warehouse/refrigeration-operator-ammonia-technician