Laboratories and life-science facilities

Biorepository Core Manager

Also posted as Biorepository Manager, Biobank Operations Manager, Biospecimen Resource Manager, Sample Management / Freezer Farm Manager, Chief technologist / biorepository manager (CAP checklist wording), Biorepository Core Director (small cores)

See it in the graph

Owns the sample store: the freezer farm of -80C ultra-low freezers, vapor-phase liquid nitrogen tanks and refrigerators across sites, their maintenance, calibration, relocation and sensor coverage on the continuous alarm monitoring system, temperature-trend review, the escalation chain for critical alarms including after-hours coverage, and the specimen chain of custody from receipt and accessioning through storage, retrieval and transport. Keeps the physical inventory matched to the electronic record, writes the SOPs, hosts sponsor and customer audits, and reconciles monthly chargeback billing. The role sits where a decade of research can be lost in a week if a freezer fails silently.

What they do

  • Oversee freezers and supporting equipment across sites: maintenance and service, calibration documentation, relocations and sensor installation
  • Coordinate continuous alarm monitoring (CAMS), review temperature trends and maintain escalation processes for critical alarms with after-hours coverage
  • Direct specimen receipt, accessioning, storage, retrieval and secure transport between locations; keep physical inventory aligned with electronic records with data-quality checks
  • Develop, maintain and implement SOPs and work practices; coordinate sponsor and customer audits and follow-up actions
  • Configure the specimen system (OpenSpecimen study builds, labels, user access) and the chargeback system (iLabs account setup, monthly charge reconciliation)
  • Assess staffing needs, recruit, train and cross-train technicians; build relationships with security, fire and police as after-hours responders
  • Keep the store audit-ready for CAP Biorepository Accreditation or ISBER best practices: alarm tests at least quarterly, emergency power and load tests, 10 percent backup storage capacity, temperature mapping
  • Handle liquid nitrogen and dry ice safely; ensure oxygen sensors or sufficient airflow where LN2 is used

What they measure

  • Freezer and LN2 tank hours outside acceptable range
  • Critical alarm response time from notification to corrective action
  • Alarm system tests completed at least quarterly per unit
  • Physical-to-electronic inventory match rate
  • Specimens lost to equipment failure
  • Backup storage capacity (CAP cites 10 percent per unit type)
  • Audit findings open
  • Monthly chargeback reconciliation accuracy
  • Freezer PM and calibration currency

Systems they use

  • Continuous alarm monitoring system (CAMS) with text, email and phone alerts
  • OpenSpecimen or another biospecimen LIMS
  • iLabs (core billing and chargeback)
  • Ultra-low temperature freezers, vapor-phase LN2 tanks with automatic refill, cold rooms
  • Freezer and LN2 tank sensors (temperature, LN2 level, auto-refill status)
  • Emergency power and CO2 or LN2 backup injection
  • CMMS or vendor service records for freezer PM
  • Excel, Word, PowerPoint

Certifications

  • Bachelor's degree required, Master's preferred (Dana-Farber)
  • 5+ years in a healthcare laboratory, biorepository or clinical research environment with prior supervisory experience
  • ISBER Best Practices and CAP Biorepository Accreditation Program familiarity
  • DOT/IATA shipping of biological specimens
  • Liquid nitrogen and dry ice safe handling

Jobs to be done

  • Catch the silent freezer failure before samples thaw · UptimeWhen a -80C freezer or LN2 tank starts drifting, I want to see the trend and the alarm routed to the on-call chain with proof it was acknowledged, so I can move samples to backup before a decade of research is lost rather than find a thawed unit a week later. AlertsBoardWorkflow
  • Prove every alarm was tested and every unit has backup · ComplianceWhen an accreditation inspector or sponsor audits the store, I want to see each unit's quarterly alarm test, calibration, temperature mapping, emergency power load test and backup capacity on one record, so I can show compliance with CAP and ISBER practice without assembling binders. ChecklistReport
  • Keep the physical inventory matched to the electronic record · QualityWhen specimens move between freezers, sites or sponsors, I want to see every aliquot's box, rack and unit position updated with chain-of-custody events, so I can retrieve any sample on request and pass data-quality checks before an audit finds the gap. WorkflowBoard
  • Cover after hours and holidays without depending on a custodian · ResilienceWhen an alarm fires at night or over a holiday, I want to see the right responder, the unit's documented procedure and the backup plan in the alert, so I can avoid the untrained first responder who silences the alarm or switches off the freezer. AlertsChecklistSchedule
  • Bill cores accurately and size the freezer farm · CostWhen the month closes, I want to see storage usage per study and investigator reconciled to iLabs charges and freezer occupancy, so I can bill accurately and show when the farm needs another unit or a defrost and purge campaign. ReportBoard

Pain points

  • Dana-Farber's Biorepository Core Manager owns freezer farm readiness across sites, CAMS monitoring and after-hours escalation, specimen chain of custody, SOPs, sponsor audits and iLabs billing, supervising 2 to 6 staff at $77,600-$88,100. (heard in Biorepository Core Manager - Breast Oncology (JR-6474), Dana-Farber Cancer Institute careers)
  • Over the 2023 Christmas holidays at Karolinska Institutet, LN2 auto-refill stopped on 16 of 19 cryogenic tanks and about 47,100 samples were lost over about five days; at McLean Hospital in 2012 a brain bank freezer's controls failed and alarms never triggered. (heard in R&D World: Cold storage might need more attention than you think (Dec 2025))
  • A university's -80C freezer failed with no alarm or notification; the meltdown went unnoticed for over a week and a decade of research material was lost; a thawed freezer can also release hazardous chemicals, radioactive material or viable microorganisms. (heard in Columbia EH&S Santayana Report: Avoiding Meltdown (September 2014); as cited in the harvest)
  • Kryosphere's biorepository technician posting puts the technician in charge of day-to-day 24/7 biorepository operations and requires being on call to return to the facility after hours, weekends and holidays. (heard in BioRepository Technician, Kryosphere (Raleigh, NC))

Sources

More roles in laboratories and life-science facilities

Every kind of facility

Every job category

See it in the graphAll of PersonaDBBuild an app for this role with Rivet

From PersonaDB, Mapped’s directory of who works in a facility and what they’re trying to get done. Every sourced entry links to the page it came from. PersonaDB’s words are free to reuse under CC BY 4.0 with credit to Mapped; the pages it cites keep their own terms. Cite as: “Biorepository Core Manager”, PersonaDB, Mapped, https://rivet.mapped.com/personas/role/laboratory/biorepository-core-manager