Runs a BSL-3/ABSL-3 suite day to day: leads the compliance team and work-practice training, manages clearance and access, oversees all facility documentation, coordinates annual facility verification with facilities and EHS, and is the operational owner of containment-critical systems (directional airflow, HEPA exhaust, interlocks, autoclaves, decontamination). Also serves as the restricted-lab access control owner in many institutions.

What they do

  • Lead the BSL-3 compliance team and BSL-3 work practices training
  • Manage clearance and access to the containment suite; maintain approved-user lists and access records
  • Oversee all BSL-3 documentation: SOPs, facility verification, maintenance and decontamination records
  • Coordinate with facilities on exhaust, HEPA, pressure, interlock and autoclave maintenance and annual verification
  • Support IBC/BSL-3 subcommittee and inspections by CDC/USDA/NIH

What they measure

  • pressure/airflow alarms in suite
  • access violations
  • annual verification complete
  • training currency of approved users

Systems they use

  • access control / badge system
  • BMS room pressure monitoring
  • training and clearance records
  • autoclave and decon logs
  • CMMS

Certifications

  • RBP
  • CBSP

Standards they work to

  • Federal Select Agent Program BSL-3 airflow requirement: Under failure conditions airflow must not reverse; HVAC verification tests exhaust-fan and power failure, with smoke or dry ice at the door to confirm no escape.

Jobs to be done

  • Reconcile containment access with approvals · SecurityWhen only cleared, trained and medically current staff may enter containment, I want badge access reconciled against the clearance list daily and entries logged, so I can keep biosecurity records inspection-ready. ReportAlertsBoard
  • Know the suite is safe to enter · SafetyWhen staff arrive to work in containment, I want current directional airflow, exhaust/HEPA status and any facilities work in progress displayed at the entry, so I can stop entry when containment is compromised. BoardAlerts
  • Verify containment systems annually with facilities · ComplianceWhen annual facility verification covers exhaust HEPA, interlocks, autoclaves and decon systems, I want each test and its evidence tracked with facilities work orders, so I can certify the suite on time and keep documentation complete. ChecklistWorkflowReport

Pain points

  • Vapor-phase decontamination can fail when a space cannot hold the decon charge long enough; uncontrollable humidity may indicate exterior leakage into the suite. (heard in Facilitiesnet: 9 Questions Probe Weaknesses of BSL3 Labs (2015))
  • In June 2007 lightning struck around CDC's new, not yet operational BSL-4 facility in Atlanta after construction workers had cut a buried grounding cable unnoticed; breakers isolated the backup generators, the building was left on emergency battery power, the negative air pressure system shut down, and staff took about an hour to reset the breakers. (heard in GAO-09-574, High-Containment Laboratories: National Strategy for Oversight Is Needed (2009))
  • In July 2008 a bird strike on a transformer cut primary power to CDC buildings with BSL-3 labs; one backup generator failed in a cascade and the negative-air fans shut down. CDC tested backup power monthly but could not document any instance of the generators operating as designed. (heard in GAO-09-574, High-Containment Laboratories: National Strategy for Oversight Is Needed (2009))
  • GAO found that high-containment lab incidents revealed a failure to fund ongoing facility maintenance and to monitor how well physical infrastructure works, and warned that maintenance and testing costs will rise as facilities age. (heard in GAO-09-574, High-Containment Laboratories: National Strategy for Oversight Is Needed (2009))

Sources

More roles in laboratories and life-science facilities

Every kind of facility

Every job category

See it in the graphAll of PersonaDBBuild an app for this role with Rivet

From PersonaDB, Mapped’s directory of who works in a facility and what they’re trying to get done. Every sourced entry links to the page it came from. PersonaDB’s words are free to reuse under CC BY 4.0 with credit to Mapped; the pages it cites keep their own terms. Cite as: “BSL-3 / High-Containment Facility Manager”, PersonaDB, Mapped, https://rivet.mapped.com/personas/role/laboratory/bsl3-facility-manager