Utilities and critical process infrastructure

Laboratory Supervisor / Water Quality Analyst

Also posted as Water Quality Control Laboratory Supervisor, Laboratory Analyst, Water Quality Specialist, Laboratory Technician (wastewater), Chemist (utility), Lab Manager

See it in the graph

Working supervisor accountable for the technical quality of every result the lab reports: reviews all data before it is final, keeps chain-of-custody and hold times, schedules analyses of wastewater, potable water, industrial wastewater and sludge, runs QA/QC and accreditation, coordinates outside labs, liaises with regulators and prepares industrial-user billing data. Holds a state lab analyst grade.

What they do

  • Run daily laboratory operations and be responsible for the overall technical quality of the work; review all data before it is reported
  • Schedule projects and track completion against deadlines and sample hold times; oversee chain-of-custody intake
  • Ensure chemical and bacteriological testing complies with state and NPDES requirements; maintain laboratory accreditation and QA/QC
  • Coordinate sampling and analyses including outside laboratories; evaluate new instruments and develop methods
  • Act as liaison with regulatory agencies; prepare billing data for industrial wastewater users; contribute to budget and staffing

What they measure

  • results reviewed and reported on time
  • hold-time violations
  • QC failures and re-runs
  • accreditation findings
  • DMR data completeness
  • turnaround time

Systems they use

  • LIMS or spreadsheets
  • bench instruments (spectrophotometers, incubators, autoclaves, BOD/TSS equipment)
  • online analyzers (as data consumer)
  • chain-of-custody records
  • DMR preparation

Certifications

  • CWEA Laboratory Analyst Grade II/III or AWWA CA-NV Water Quality Laboratory Analyst Grade III
  • state lab accreditation (ELAP or equivalent) maintained by the lab
  • bachelor's in chemistry, biology or microbiology typical

Jobs to be done

  • Never miss a hold time · ComplianceWhen dozens of samples arrive with different hold times, I want every sample's clock, preservation and assigned analyst visible, so I can sequence the bench and never report a result that was out of hold. BoardAlertsSchedule
  • Reconcile the lab with the online analyzers · QualityWhen bench results and online analyzers disagree, I want the two trended together by sample point, so I can catch a drifting analyzer or a bad bench method before either reaches a DMR. BoardReport
  • Bill and police the industrial users · ComplianceWhen industrial dischargers pay by strength and must stay within local limits, I want their sampling results, permit limits and surcharge calculations together, so I can bill accurately and flag a violation the week it happens. ReportAlertsWorkflow

Pain points

  • Much of the process lab equipment and supplies were outdated, analyses took a long time and operators took shortcuts; sampling tubing was not replaced when needed. (heard in Maryland Environmental Service: Back River WWTP Assessment Report (2022))
  • O*NET's Environmental Science and Protection Technicians occupation includes titles such as Lab Technician, Sanitarian and Water Quality Specialist; its tasks include collecting industrial wastewater samples and investigating spills. (heard in O*NET 19-4042.00 Environmental Science and Protection Technicians)
  • At El Reno, Oklahoma, the project manager of the Veolia-operated plant mixed effluent grab samples with bleach, held them past the maximum holding time and diluted them before sending them to the certified lab to cut E. coli counts; a plant lab worker later told a DEQ investigator she had seen him tamper with samples. (heard in El Reno wastewater treatment plant manager admits fraud (Southwest Ledger))
  • A New Mexico NPDES inspection rated a small WWTP's laboratory unsatisfactory: no pH calibration records, no duplicate samples for any parameter, and the person running compliance analyses lacked the required Wastewater Laboratory Tech I certification. (heard in NMED NPDES Compliance Evaluation Inspection, NM0028479 (Jemez Public Schools WWTP))
  • San Diego's auditor found many industrial wastewater permit and monitoring fees unchanged since 1984: of about $38.8 million in program costs (FY2010-2019) only $5.5 million (14 percent) was recovered from permittees, and many outside-city permittees again went unbilled from FY2017. (heard in San Diego OCA-21-001: Follow-Up Performance Audit of the Industrial Wastewater Control Program)
  • Seattle's auditor found high-strength industrial waste and contaminated stormwater volumes used for billing are self-reported by customers with little verification, construction dewatering volumes almost unverified, and sewer submeters not tested for accuracy. (heard in Seattle Office of City Auditor: SPU Wastewater Revenue Cycle audit (2011 committee packet))

Sources

More roles in utilities and critical process infrastructure

Every kind of facility

Every job category

See it in the graphAll of PersonaDBBuild an app for this role with Rivet

From PersonaDB, Mapped’s directory of who works in a facility and what they’re trying to get done. Every sourced entry links to the page it came from. PersonaDB’s words are free to reuse under CC BY 4.0 with credit to Mapped; the pages it cites keep their own terms. Cite as: “Laboratory Supervisor / Water Quality Analyst”, PersonaDB, Mapped, https://rivet.mapped.com/personas/role/utilities-infrastructure/laboratory-supervisor