Utilities and critical process infrastructure

Substation Electrician / Relay Technician

Also posted as Substation Technician, Protective Relay Technician, Substation Mechanic, Substation Wireman, Electrical and Instrumentation Technician (substation), Substation Relay SCADA Technician

See it in the graph

Installs, tests, maintains and repairs substation equipment and protective relays: breakers, power transformers, switches, battery banks and chargers, regulators, reclosers, RTUs and SCADA communication; inspects substations and records data in logs; operates high-voltage switching to isolate circuits; and responds to trouble calls and outages after hours. Trained through a two-year degree or apprenticeship; a shortage of qualified technicians led one community college and two utilities to build a two-year program.

What they do

  • Inspect and test equipment and circuits to find faults using wiring diagrams and meters; analyse test data to diagnose malfunctions
  • Switch circuits to isolate defective relays and repair or replace them; repair breakers, transformers, battery chargers and battery banks
  • Inspect and monitor substations and record data in logs; notify facility personnel when equipment will be shut down
  • Maintain and test SCADA/RTU, reclosers, padmount switches and regulators; run signal quality tests on cables
  • Operate high-voltage switching devices; operate cranes, bucket trucks and manlifts; respond to on-call and emergency call-back

What they measure

  • relay misoperations
  • substation inspections completed
  • battery bank tests current
  • trouble call response time
  • maintenance records complete (NERC PRC-005 style)

Systems they use

  • SCADA / RTU
  • relay test sets (OMICRON Test Universe, Megger PowerDB, Doble)
  • transformer turns-ratio and breaker testers, DMMs, phasing sticks
  • Fluke FlukeView Forms
  • AutoCAD drawings
  • maintenance records / CMMS

Certifications

  • post-secondary certificate or associate degree (half of new hires); apprenticeship: Relay Technician, Electrician (Substation)
  • Class A CDL within 120 days (Austin)
  • confined space air monitoring, PPE/PPD

Jobs to be done

  • Inspect every substation and log it once · MaintenanceWhen I inspect substations and record data in logs, I want readings, battery checks and defects captured against each asset on a mobile device with the last inspection beside them, so I can find the trend and the log is already written. ChecklistMapAlerts
  • Test the relays on time with the right settings · ComplianceWhen protective relays must be tested on an interval and settings change with the system, I want each relay's settings file, last test result and due date together, so I can test what is due and prove the protection zones are right. ScheduleReportChecklist
  • Switch safely on a night callout · SafetyWhen I am called back for an outage and must isolate a circuit by high-voltage switching, I want the switching order, clearance status and who else is on site before I touch anything, so I can work it safely with the dispatcher. WorkflowChecklist

Pain points

  • A shortage of qualified relay and substation maintenance technicians led a community college and two utilities to build a two-year degree designed to shave two to three years off entry-level training. (heard in T&D World: Substation and Relay Lab Leader (2014))
  • Substation work is strenuous in all weather at elevated positions, with confined-space entries requiring air monitoring (Austin Energy). (heard in City of Austin (Austin Energy): Substation Electrician III job description)
  • NERC describes line relays put in service with the wrong CT ratio and transformer relays missing a residual-circuit connection; both defects went undetected until a disturbance, when misoperation increased the disturbance's magnitude and scope and, in the second event, caused significant loss of load. (heard in NERC Lessons Learned Webinar: LL20200702 Verification of AC Quantities during Protection System Design and Commissioning)
  • In-service CT checks carry a shock hazard: an open circuit on an in-service CT can produce 1,000 volts or more, and isolating relays for testing must account for a fault on the primary equipment meanwhile. (heard in NERC Lessons Learned Webinar: LL20200702 Verification of AC Quantities during Protection System Design and Commissioning)
  • An industrial owner with over 100 substations built 1957-2007 says it has 'one of everything', so a work method that suits one does not suit all; vendors refused control-compartment work without de-energizing gear that cannot easily be taken down. (heard in Electrical Equipment Service (Mike Holt's Forum))

Sources

More roles in utilities and critical process infrastructure

Every kind of facility

Every job category

See it in the graphAll of PersonaDBBuild an app for this role with Rivet

From PersonaDB, Mapped’s directory of who works in a facility and what they’re trying to get done. Every sourced entry links to the page it came from. PersonaDB’s words are free to reuse under CC BY 4.0 with credit to Mapped; the pages it cites keep their own terms. Cite as: “Substation Electrician / Relay Technician”, PersonaDB, Mapped, https://rivet.mapped.com/personas/role/utilities-infrastructure/substation-relay-technician