Electrical / Instrumentation & Controls Technician

Also posted as E&I Technician, I&C Tech, Electrical Maintenance Technician, Industrial Electrician, PLC Controls Technician, Instrument Technician, Control Technician, Electronic Technician, Automation Technician, E and I Mechanic, Electrical and Instrument Technician, I and C Technician, I and E Technician, Scale Technician

See it in the graph

Troubleshoots drives, sensors, PLC I/O and power distribution on the floor, calibrates instruments, keeps equipment logs and performs electrical PMs. The person who makes an after-hours logic change to restore production, and who may or may not document it.

What they do

  • Test faulty equipment to diagnose malfunctions, using test equipment or software (O*NET)
  • Maintain equipment logs that record performance problems, repairs, calibrations, or tests (O*NET)
  • Perform scheduled preventive maintenance tasks to detect and prevent problems (O*NET)
  • Enter information into computer to copy program or to draw, modify, or store schematics (O*NET)
  • Maintain system logs or manuals to document testing or operation of equipment (O*NET 17-3023)

What they measure

  • electrical MTTR
  • calibrations on time
  • arc-flash incidents (zero)
  • PM completion
  • undocumented program changes (zero)
  • Calibration interval by failure rate

Systems they use

  • Rockwell RSLogix/Studio 5000, Siemens TIA (fairlife posting names Allen Bradley & Siemens)
  • AVEVA InTouch HMI
  • SCADA
  • SAP Maintenance / CMMS
  • calibration management
  • AutoCAD electrical drawings
  • Fluke 744 documenting process calibrator

Certifications

  • journeyman electrician licence (state)
  • NFPA 70E qualified person
  • ISA CCST (inferred)
  • EPA 608 if touching refrigeration

Jobs to be done

  • Document the 2am logic change · IT and OTWhen I change ladder logic or a setpoint to restore production, I want the change, the reason and the backup captured in the same motion, so a rung tweaked at 2 AM does not become the cause of next month's downtime. WorkflowChecklistAlerts
  • See the drive and sensor faults before the call · UptimeWhen a VFD trips repeatedly or a sensor drifts, I want the fault codes and trend from the controller surfaced to me, so I can fix the root cause on a PM rather than keep resetting it on calls. AlertsBoard
  • Work energized only with current arc flash data · SafetyWhen I open a panel, I want the arc-flash label, incident energy and required PPE to reflect the current single-line and relay settings, so I am not trusting a label that went stale the day after it was installed. MapChecklistReport

Pain points

  • Maintenance electricians who knew relay logic 'had never worked with PLCs' after a new SCADA commissioning (search summary, interview prep) (heard in O*NET 17-3023.00 Electrical and Electronic Engineering Technologists and Technicians)
  • On a PLCtalk thread started by an electrician at a 100-year-old company with no prints for most machines, a respondent says the lasting fix is ringing out the wiring into drawings, which can take days; without time, all you can do is inspect devices with a flashlight and magnifier. (heard in Electrical Troubleshooting (PLCtalk))
  • A semi-retired engineer on Mike Holt's Forum says he has often had to tell people they are out of luck: an old HMI died, there is no backup of its configuration, and the replacement bought on eBay has not been made for 20 years, often by a maker no longer around. (heard in Electrical maintenance (Mike Holt's Forum))
  • Experienced maintenance electricians on the same thread say most electricians just want to get the job done and do not keep records current, so drawings and panel schedules drift from the installed equipment unless redlines are captured and sent back for updating. (heard in Electrical maintenance (Mike Holt's Forum))
  • A PLCtalk poster found a reactor pressure transmitter had run six years on its factory calibration because it fell through the documentation cracks, while the controller and chart recorder on the same loop were calibrated twice a year under ISO. (heard in Reasons for calibration, page 2 (PLCtalk))
  • A PLCtalk thread starter wants to persuade management that keeping a full-time calibration technician and calibrated meters saves money, and plans to put it in waste and profit-per-hour terms management will understand. (heard in Reasons for calibration, page 2 (PLCtalk))

Sources

More roles in manufacturing plants and industrial sites

Every kind of facility

Every job category

See it in the graphAll of PersonaDBBuild an app for this role with Rivet

From PersonaDB, Mapped’s directory of who works in a facility and what they’re trying to get done. Every sourced entry links to the page it came from. PersonaDB’s words are free to reuse under CC BY 4.0 with credit to Mapped; the pages it cites keep their own terms. Cite as: “Electrical / Instrumentation & Controls Technician”, PersonaDB, Mapped, https://rivet.mapped.com/personas/role/manufacturing/electrical-instrumentation-controls-technician