Manufacturing plants and industrial sites

Energy Manager (plant / ISO 50001)

Also posted as Plant Energy Manager, Energy Site Manager, Energy and Sustainability Manager, Energy Engineer, Industrial Energy Engineer, Utilities Manager (energy focus), Energy Efficiency Engineer

See it in the graph

Owns the plant's energy management system: serves as ISO 50001 management representative, sets EnPIs, baselines and targets, runs audits of compressed air, pumps, fans, thermal processes and dust collection, manages energy monitoring software and dashboards, verifies savings with M&V and reports to corporate and national schemes.

What they do

  • Serve as the Management Representative for ISO 50001, leading all aspects of the Energy Management System (Insight Global posting, via search)
  • Develop and maintain EnPIs, baselines, and improvement targets (via search)
  • Manage the integration and optimization of energy monitoring software and dashboards (via search)
  • Collect data for energy conservation analyses, using jobsite observation, field inspections, or sub-metering (O*NET)
  • Conduct energy audits to evaluate energy use and to identify conservation and cost reduction measures (O*NET)
  • Energy data collection and national efficiency reporting accuracy (Hershey Johor, via search)

What they measure

  • EnPIs (kWh per unit, therms per unit)
  • energy cost per unit
  • verified savings vs target
  • compressed air specific power
  • peak demand charges
  • ISO 50001 audit findings
  • Steam loss per failed trap
  • Peak 15/30-minute demand (kW)
  • Power factor
  • Energy consumption (kWh)
  • Compressed air kW per 100 cfm
  • Steam cost per 1,000 lb
  • Cost of compressed air per MMscf

Systems they use

  • energy monitoring / EMIS with submeters
  • BMS
  • compressor and chiller controls
  • utility billing data
  • ISO 50001 documentation
  • M&V spreadsheets/tools
  • Trane System Analyzer, MATLAB (O*NET)
  • AirMaster+

Certifications

  • AEE CEM
  • ISO 50001 lead auditor / 50001 CP
  • CEA (energy auditor)
  • BSc ME/EE/energy engineering

Jobs to be done

  • See energy per unit by line and shift · EnergyWhen reviewing EnPIs, I want submetered energy normalised by production per line and shift, so I can separate real efficiency change from volume change and report to corporate with numbers that survive M&V. BoardReportScorecard
  • Find off shift and idle load · EnergyWhen the plant is down, I want to see what is still drawing power, air and steam, so I can shut down idle equipment and leaks that run through weekends unnoticed. BoardAlertsReport
  • Prioritise audit findings into funded projects · CostWhen an audit finds opportunities in compressed air, pumps, fans or process heat, I want each sized with cost, savings and payback and tracked to completion with M&V, so I can convert findings into projects that finance approves. WorkflowReport
  • Keep ISO 50001 evidence current · ComplianceWhen the ISO 50001 surveillance audit comes, I want significant energy uses, monitoring plans, EnPI reviews and management review minutes in one maintained system, so I can pass without a document scramble. ChecklistReport

Pain points

  • ISO 50001 is not part of the CEM body of knowledge; a separate 50001 CP credential exists (heard in AEE Certified Energy Manager)
  • A PLCtalk respondent on reducing plant energy says leaks cost a lot and points at wasteful compressed-air practices such as sweeping floors with air. (heard in Ideas to reduce energy use (PLCtalk))
  • An IndustryWeek column (2017) by an energy-management consultant says submetering plans often specify too many points (maybe as many as 350), sub-meters don't monitor themselves, and within three years about 20% of meters aren't working as planned because nobody monitored them. (heard in The Big Problem with Sub-metering Energy Usage (IndustryWeek, 2017-05-23))
  • DOE warns that fixing leaks alone does not cut the bill: compressor controls must be re-adjusted so run time falls to match the lower demand, and leak fixing must be a recurring program (tagging, tracking, repair, verification) rather than a one-off. (heard in Minimize Compressed Air Leaks (US DOE Compressed Air Tip Sheet #3, revised 2004-08))
  • A copper wire plant's attempts to cut compressed air by taking air wipes out of service caused quality problems: process liquid carried into downstream chemical tanks contaminated them, with $30K to $40K to replace spoiled chemicals and risk to plating quality, so savings were sought by lowering air wipe pressure instead. (heard in International Wire Trims Compressed Air Costs Using the Systems Approach (Compressed Air Challenge, reprinted from Compressed Air Best Practices, 2012-03))
  • The same plant's 2010 baseline measured compressed air demand of 969 scfm on weekends against 995 scfm on weekdays, with five compressors installed at four locations after years of growth. (heard in International Wire Trims Compressed Air Costs Using the Systems Approach (Compressed Air Challenge, reprinted from Compressed Air Best Practices, 2012-03))
  • Compressed Air Challenge material describes 'artificial demand': running unregulated end uses at higher pressure than they need increases air consumption with no production benefit; the wire plant targeted it by regulating air wipe pressure. (heard in International Wire Trims Compressed Air Costs Using the Systems Approach (Compressed Air Challenge, reprinted from Compressed Air Best Practices, 2012-03))

Sources

More roles in manufacturing plants and industrial sites

Every kind of facility

Every job category

See it in the graphAll of PersonaDBBuild an app for this role with Rivet

From PersonaDB, Mapped’s directory of who works in a facility and what they’re trying to get done. Every sourced entry links to the page it came from. PersonaDB’s words are free to reuse under CC BY 4.0 with credit to Mapped; the pages it cites keep their own terms. Cite as: “Energy Manager (plant / ISO 50001)”, PersonaDB, Mapped, https://rivet.mapped.com/personas/role/manufacturing/energy-manager